PERFUSION REPORTS
Perfusion Reports are taken from the Safety Committee web based reporting system and after appropriate anonymising disseminated to the membership. The content should be informative and hopefully encourage similar sharing from the perfusion community. Select any of the options below to go to a dedicated perfusion reports page.
Select and scroll to view chosen report
Sucker Placed In Raceway In Wrong Direction
High Transmembrane Pressure Gradients
Faulty Connector On ECMO Soft Shell Reservoir Bag
Sorin Inspire 8F Blood Leak From Temperature Port
Sorin Inspire 8F Oxygenator Detached From Holding Arm
Paragon Oxygenator Gas Inlet Leak
Maquet IABP Console Failure
Sorin EOS Gas To Blood Leak Whilst Priming
Chalice Paragon Midi Heat Exchanger Leak Whilst Priming
Chalice Paragon Heat Exchanger Water To Blood Leak
Vent Pump Boot Tubing Inserted In Wrong Way Round
Paragon Oxygenator Heat Exchanger Leak
Medtronic Potential Oxygenator Leak
Medos Heat Exchanger Leak
Avant D903 Has A Dual Chamber Reservoir Leak
Additional Sucker Incorrectly Placed In Raceway
Large Perished Tear Observed On Tubing At Back Of Vaporiser
Gas Blender Flow Control Immobilised
Isoflurane Vaporiser Seal Leak Due To Malposition
Hypercoagulable Disorder May Have Led To Oxygenator Failure
LV Vent Placed In Raceway In Wrong Direction
Sucker Placed In Raceway In Wrong Direction
Similarity In Heparin And St Thomas Cardioplegia Ampules
Aorta Remained Clamped Post CPB
Deficiencies In The QC At Terumo Ann Arbor, USA.
Awareness Of Suckers When Using Bio-Glues
Patient Exsanguinated From Additional Venous Line Post CPB
Possible Inaccuracies In Colloid Research
Difficulties In Visualising Blender Reading
Perfusion Report cards are shown in batches of 30 at any one time.
Know the report number? Scroll horizontally through the circle icons and select to view the appropriate report.
FIELD SAFETY NOTICES (FSN)
A ‘field safety notice’ (FSN) is an important communication about the safety of a medical device that is sent to customers by a device manufacturer, or their representative. FSNs tell you what you need to do to reduce the specified risks of using the medical device. The actions are referred to as ‘field safety corrective actions’ (FSCAs). If you receive a field safety notice from a manufacturer, always act on it. Select any of the options below to go to a dedicated FSN page.
Select and scroll to view chosen report
Getinge HCU40 Replacment of Vacuum Valves
Getinge Replacement IFU's for HU35 and rotaflow console
Liva Nova Perceval Valve Accessory kit
Medtronic HeartWare HVAD system lubricant
Getinge Quadrox Holder FSN
Medtronic HeartWare HVAD Systems
Infections Associated With HCUs In CPB & ECMO
Potential Mycobacterial Contamination Of HCUs
SWISSMEDIC: Water-Borne Infection In Implant Patients
Maquet Cardioplegia Temperature Reading Inaccuracies
Maquet Adhesive Failure On Oxygenator Blood Outlet Connector
Sorin Heat Exchanger Blood Water Leak
Maquet Transient Increase In Pump Speeds
Terumo CDI500 Possibility Of Parameter Drift
Datascope IABP Harness Not Fit For Purpose
FSN Report cards are shown in batches of 18 at any one time.
Know the report number? Scroll horizontally through the circle icons and select to view the appropriate report.